■ Modified hybrid primer with tar
■ Ideal for horizontal joints in pavements of airports, industries, garages, gas stations, parking lots, tunnels, galleries and sewage treatment plants
■ Self leveling
■ High chemical resistance
■ High handling capacity
■ Resistant to weathering
Polymer-based single-component sealant with modified silanes and tar. Product that cures at room temperature through air humidity and becomes a flexible rubber with resistance to chemicals.
It is suitable for use in joints of external areas, cement and resin industrial floors, gas stations, courtyards (road, port or airport), basins, containment tanks, galleries and sewage treatment plants.
Color | Packaging | |
---|---|---|
Black RAL9017 | Sachet 600mL | Bucket 25kg |
Method | Test | Unity | Result |
---|---|---|---|
ME-002 | Skin formation | min | 60 |
ME-013 | Curing rate | mm/24h | 3 |
ASTM D 792 | Density | g/cm3 | 1,42 |
PROPERTY AFTER HEALING | |||
ASTM D 2240 | Durometer Hardness | Shore A | 30 |
ASTM D 412 | Tension at break | MPa | 1,5 |
ASTM D 412 | Elongation at break | % | 400 |
ME-015 | Temperature resistance | °C | -20 / +80 |
ISSO 1160 | Handling capacity | % | +/- 25 |
SURFACE PREPARATION:
The surface must be dry, clean, free of dust and oils. To promote a deep cleaning of the joint initially with a steel brush, soon after using the vacuum cleaner or blower, the joint must be free of any dust, residues or any other type of material (organic or inorganic) that prevents perfect anchorage , for a more efficient cleaning we also advise the application of ethanol with the help of a brush. Remove all wastes from materials, especially those that are not sufficiently adhered to the layers (sanding, if necessary). For better finishing it is recommended to use adhesive tape in the lateral areas of the joint where the contact of the product is not intended. In the case of applications on substrates other than those mentioned in this bulletin, it is recommended to carry out a test to evaluate the adhesion and compatibility of the product.
HOW TO USE:
Apply the product to the desired area and immediately do the finishing. In case of using tape remove it before it forms film. After use, leave a small amount of product above the nozzle to form a tampon. In reuse, remove the plug. After open reuse the product in up to one week. Clean tools before curing. After curing the product is only mechanically removed.
Conditions of Use / Limitations:
Min Substrate Temperature:
10ºC / Maximum: 30ºC
Minimum Ambient Temperature:
10ºC / Maximum: 30ºC
■ Modified hybrid primer with tar
■ Ideal for horizontal joints in pavements of airports, industries, garages, gas stations, parking lots, tunnels, galleries and sewage treatment plants
■ Self leveling
■ High chemical resistance
■ High handling capacity
■ Resistant to weathering
■ Do not use on rolled glass, corrosive metals, mirrors and painted surfaces.
■ Do not apply to plastics based on polyethylene, polypropylene, polycarbonate, acrylic and polytetrafluoroethylene.
■ Do not use on glass facades and any structural adhesion that needs resistance.
The product should be kept in its original packaging and stored in a cool place at a temperature of 5 to 30°C, away from direct sunlight and away from heat sources. To avoid contamination of the unused product, do not return any leftover material in its original packaging. Keep out of reach of children and pets.
Validity (from the date of manufacture): 6 months.
Except Bucket: 4 months.